Skip to content

Multi-probe Dallas splitter support, SEN55 read fix, fleet diagnostics (26.11.12.1) - #37

Merged
Bunton33 merged 6 commits into
mainfrom
claude/dallas-multi-probe-eca486
Nov 12, 2026
Merged

Bunton33 merged 6 commits into
mainfrom
claude/dallas-multi-probe-eca486

Conversation

@Bunton33

@Bunton33 Bunton33 commented Oct 21, 2026 •

Copy link
Copy Markdown
Contributor

Version: 26.11.12.1

What does this implement/fix?

Adds multi-probe Dallas support (up to 4 probes on the 3.5 mm splitter; probes 2-4 disabled by default), fixes the SEN55 read collision that dropped a reading on every deep-sleep wake, and adds the fleet-standard diagnostics (ESPHome/Apollo Firmware Version, IP/MAC, plus RSSI/SSID/BSSID on WiFi). No existing entities are renamed or removed, and the OTA from production 26.5.20.1 was bench-tested on WiFi and Ethernet (about 30 h on Ethernet with 0 crashes). Ethernet risk: since ESPHome 2026.6 the W5500 driver can hit an unfixed ESP-IDF race (espressif/esp-idf#18527, esphome/esphome#18974), so roll out to one WiFi and one Ethernet unit first and watch Uptime before the rest; battery units should update with Prevent Sleep on.

Types of changes

  • Bugfix (fixed change that fixes an issue)
  • New feature (thanks!)
  • Breaking change (repair/feature that breaks existing functionality)
  • Dependency Update - Does not publish
  • Other - Does not publish
  • Website of github readme file update - Does not publish
  • Github workflows - Does not publish

Checklist / Checklijst:

  • The code change has been tested and works locally
  • The code change has not yet been tested

If user-visible functionality or configuration variables are added/modified:

  • Added/updated documentation for the web page

🤖 Generated with Claude Code

Bunton33 and others added 3 commits October 19, 2026 01:18
Port TEMP-1's multi-probe change (TEMP-1 2af97e2) so up to four Dallas
probes can share the left 3.5mm port through the Multi-Probe Splitter
with no yaml edits.

- Existing probe (dallas_temp_probe, "Temperature Probe (Dallas)") gets
  index: 0. Its id and name are unchanged, so HA entities carry over.
  Without an index it refused to read anything once a second probe was
  on the bus ("More than one device, can't auto-select address").
- New dallas_temp_probe_2/3/4 at index 1/2/3, disabled by default.
- reportAllValues also updates probes 2-4 so sleeping units publish
  them before deep sleep (TEMP-1 only updates probe 1 there).
- min_version 2025.11.0: the one_wire index option first shipped in
  ESPHome 2025.11.0.
- Version 26.10.19.1.

Probe numbering follows 1-Wire ROM order, not splitter port, and is
resolved at boot. Absent indexes log one error at boot and are never
polled.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Both components talk to the SEN55 at 0x69. sen5x_number's read is
atomic (write 0x0413, blocking 20 ms delay, read), while sen55 sends
"read measurement" and reads 20 ms later from a scheduled timeout.
All component.update actions run synchronously until the script's
first delay, so with sen5x_number second its command always landed
inside sen55's window: sen55 then read 0xFF ("CRC invalid", "Read data
error (7)") and lost its reading on every deep-sleep wake.

Same fix as Updates-and-fixes, which was never merged to main.
Bench-confirmed on 26.10.19.1: one CRC error per wake before this change.

Version 26.10.19.2.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Match the diagnostics Apollo's other devices expose:
- Core: ESPHome Version (version platform, hide_timestamp) and
  Apollo Firmware Version (template text sensor published once at
  on_boot priority 500, the form TEMP-1 settled on after the
  "unknown" fix).
- WiFi: RSSI (wifi_signal, 60 s), IP Address, plus Connected SSID,
  Connected BSSID and MAC Address disabled by default (H-3 set).
- Ethernet: IP Address, plus MAC Address disabled by default.

All diagnostic category. Purely additive: no existing entity is
renamed, removed or changes domain, so HA entity ids and history
carry over. Plain "IP Address"/"MAC Address" names follow the split
R_PRO-1 and every WiFi-only product, and stay the same entity if a
unit switches between the W and ETH images.

Left out on purpose: readable uptime (the fleet PRs were closed
unmerged on 2026-10-02, and it would read "0m" on short wakes),
Network Connection (only meaningful in a unified image), API
encryption (breaks HA pairing on live units).

Version 26.10.19.3.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@coderabbitai

coderabbitai Bot commented Oct 21, 2026 •

Copy link
Copy Markdown

Important

  • Trigger review

This repository does not receive automatic reviews because it has fewer than 10 stars.

Run configuration

  • Source mode: Auto
  • Repository: Unavailable
  • Branch: Unavailable
  • File: No configuration file from this repository applied
  • Commit: Unavailable
  • Layers: Organization UI
  • Review profile: CHILL
  • Plan: Advanced
  • Run ID: cfd60cf7-ae05-44a5-a654-34c660aafb9e
  • Autofix · Keep fixing CodeRabbit findings and required CI, and resolving merge conflicts

Thanks for using CodeRabbit! It's free for OSS, and your support helps us grow. If you like it, consider giving us a shout-out.

Share

Bunton33 and others added 2 commits October 21, 2026 13:28
Comment-only change; the validated config and firmware are unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@Bunton33 Bunton33 changed the title Multi-probe Dallas splitter support, SEN55 read fix, fleet diagnostics (26.10.19.3) Multi-probe Dallas splitter support, SEN55 read fix, fleet diagnostics (26.10.21.1) Oct 21, 2026
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@Bunton33 Bunton33 changed the title Multi-probe Dallas splitter support, SEN55 read fix, fleet diagnostics (26.10.21.1) Multi-probe Dallas splitter support, SEN55 read fix, fleet diagnostics (26.11.12.1) Nov 12, 2026
@Bunton33
Bunton33 merged commit f6637d3 into main Nov 12, 2026
9 checks passed
@Bunton33
Bunton33 deleted the claude/dallas-multi-probe-eca486 branch November 12, 2026 06:24
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

new-feature New feature

Projects

None yet

Development

Successfully merging this pull request may close these issues.