Add BEOK TGM50 floor-heating thermostat (#1447) - #1558
Merged
Merged
Conversation
The interviewed _TZE204_cvub6xbb uses datapoint 2 as the setpoint, so it stays out of the BHT-002 wall_thermostat map. Writes wait for the radio and roll back on failure, and Tuya time replies use the 1970 epoch. Co-authored-by: Johan Bendz <JohanBendz@users.noreply.github.com>
This was referenced Nov 16, 2026
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Related: #1447
Tracker: #1557
Adds an isolated Homey driver for the BEOK TGM50-ZB-WP wall thermostat from the Homey interview in #1447. It is a mains-powered router,
TS0601/_TZE204_cvub6xbb, endpoint 1 server clusters 0, 4, 5 and 61184 (Tuya EF00), client clusters 25 (OTA) and 10 (Time). There is no Thermostat cluster 0x0201.wall_thermostatis unchanged. That BHT-002 profile uses datapoint 2 as the manual/program mode and datapoint 16 as the setpoint (#1479, #1501). On this thermostat datapoint 2 is the setpoint, so the fingerprint is not added there.Identity
Manifested exactly:
_TZE204_cvub6xbbTS0601Left out on purpose. Both appear in external converters and neither has a Homey interview in this repository:
_TZE284_cvub6xbb(Zigbee2MQTT and ZHA)_TZE204_mwomyz5n(Zigbee2MQTT only)Datapoint map
Confirmed from Zigbee2MQTT TGM50-ZB and the ZHA quirk. Temperatures are value ÷ 10 on read and value × 10 on write. A write is sent only after a user change, the Homey value is restored when the radio rejects it, and init does not write.
child_lockcapabilitytemp_calibrationcapabilitythermostat_heatingthermostat_presetis not reused. Its values are 0 Automatic, 1 Manual, 3 Holiday, which do not match this enum. The driver usesbeok_tgm50_preset.thermostat_heating.jsonis the same capability file as AVATTO TRV #1535, so either pull request can merge first. The visible title is Heating. The shared description text still says “the valve is heating” because that is the #1535 wording.Not exposed
Both are logged if the device reports them. Nothing writes them.
No known datapoint
Floor-probe temperature, window detection, power-loss memory and the weekly schedule are not in the Zigbee2MQTT or ZHA maps. Unmapped reports use the same 60-second limiter as
wall_thermostat: the first value and each change are logged, and identical repeats are summarized. Sensor select (DP106) chooses internal, external or both, but that is not a floor-temperature reading.Time
Zigbee2MQTT uses
timeStart: "1970". A Tuya 0x24 request is answered likelcdtemphumidsensor_3: 8 bytes, big-endian UTC seconds then local seconds, with explicitpayloadSize. The reply is sent only when the device asks. Init does not query or write.Pairing text follows Zigbee2MQTT: power on, then hold the ^ key at the bottom right for 5–8 seconds until the Wi-Fi icon flashes.
Unverified
_TZE284_cvub6xbband_TZE204_mwomyz5nmay share the map, but they are not paired by this driver.Hardware checklist for the reporter
_TZE204_cvub6xbband modelTS0601. Note whether the unit is WP or WPB.processReporting <dp> <value>. Please include the datapoint number, the value, and what you changed.