Design files for a support and interface unit for the Garmin LiDAR Lite.
- Namesake
- Technical specifications
- Assembly
- Firmware
- Writing a program to connect to the Apis
- Register map and firmware internals
- Housing and cabling
- Field installation
- Acknowledgments
With its internal guidance system and compound eyes, the honeybee can obtain orientation and range while seeing in slow motion. Those rapid eyes feel perfect for a laser, and though the bee doesn't have one – it senses distance through parallax instead – just imagine if it did.
The symbiont. Lichens, like this Reindeer Lichen found in northeastern Minnesota, are a symbiosis between fungi and algae. Our symbiosis is between silicon, copper, aluminum, and laser. But be it nature or machine, some partnerships are truly mutual in their benefits. Photo by Homer Edward Price.
The LiDAR Lite is a rangefinder from Garmin capable of returning distances to objects up to 40 m away. It is an effective sensor for water, snow, and ice levels, among other purposes. Extensive work to characterize the LiDAR Lite for environmental sensing of water levels has been performed by:
Paul, J. D., Buytaert, W., & Sah, N.(2020). A technical evaluation of lidar-based measurement of riverwater levels. Water Resources Research, 56, e2019WR026810. https://doi.org/10.1029/2019WR026810
Assembled Apis unit. The front face shows pitch and roll orientation conventions and the "zero" location (oval cutout, lower center) where the magnet is tapped to calibrate the accelerometer.
- Microcontroller (computer) core
- ATTiny1634
- Firmware written in Arduino-compatible C++
- 12 MHz
- Sensors
- Externally connected: Garmin LiDAR Lite v3 HP
- On board
- MEMS accelerometer to detect board angle
- Hall-effect sensor to for user to trigger with a magnet after providing a known angle to the accelerometer. This corrects for offset errors in the accelerometer, significantly improving its angular accuracy.
- Connections and communications protocols
- LiDAR Lite v3 HP
- 6-pin screw-terminal header
- Switchable 5V power supply
- I2C
- Data logger
- Power in and Ground
- Digital communications
- I2C
- LiDAR Lite v3 HP
- Power
- Voltage limits: 3.3 ~ 5.5V
- Power consumption: ~0.5mA @ 4.5V, take reading every 60 seconds, then power down
- Power conditioning: Provides an onboard, high power, step up to 5V to allow for interface to 3.3V loggers
- Fault recovery: Using intermediate system to emulate an I2C connection prevents a global lockup of the logger system
- Status LED
- Open-source licensing via CC BY-SA 4.0
Apis v0.1 board, top side. Minnesota quarter (24.3 mm diameter) for scale.
- Programmable using the Arduino IDE https://www.arduino.cc/en/main/software
- Firmware available in this repository.
- Software to use the Apis with Arduino-compatible devices
- Open-source licensing via GNU GPL 3.0
Assembling this sensor is possible by hand with sufficient skill and the following tools:
- Temperature-controlled soldering iron
- Hot-air rework station
- Equipment for stenciling with solder paste
- ESD-safe tweezers and workstation
- Solder wick
Most of the components on this board are coarse enough in pitch that assembly by hand is expected to be relatively straightforward. However, if you are concerned about this, there are PCB assembly workshops located in many parts of the world.
We recommend having circuit boards produced by a reputable manufacturer. Many are located in China, India, and other countries worldwide. You will need to provide the Gerber files, available in this repository alongside the board design files.
Before placing components, you will need solder paste and a stencil. A stencil allows you to apply a controlled, even amount of paste to all pads at once. If you have access to a laser cutter, you can create your own stencil; otherwise, most PCB manufacturers offer stencil production as an add-on service. In a pinch, a solder-paste syringe works but increases the risk of bridged connections. Additional guidance on stenciling is available here.
Once paste is applied, use tweezers – or a pick-and-place machine if available – to place each component onto its pads in the correct orientation. Slight misalignment is acceptable; surface tension from the molten solder will help pull components into place during reflow.
Reflowing heats the solder paste until it flows and bonds components to the board. A basic introduction is available here. Common methods include:
- Professional reflow oven – the most consistent method
- Converted toaster oven – affordable and effective; see SparkFun's guide and many other online references
- Electric skillet – surprisingly effective for simple boards; guide here
- Hot-air rework station – more labor-intensive but gives fine control; suitable for single boards or small runs; guide here
After reflow, clean up any bridged connections with solder wick.
Inspect the board carefully after reflow. Look for bridged connections, cold joints, or components that shifted out of alignment. A multimeter is essential for checking continuity and identifying shorts. An oscilloscope or logic analyzer can help verify that the microcontroller, accelerometer, and I2C bus are functioning correctly. If you are new to debugging circuit boards, working with an electrical engineering student or professional – even for a single session – can save significant time.
Go to https://www.arduino.cc/en/main/software. Choose the proper IDE version for your computer. For Windows, we suggest the non-app version to have more control over Arduino; this might change in the future. You will have to add custom libraries, so the web version will not work (at least, as of the time of writing). Download and install the Arduino IDE. Open it to begin the next steps.
To install firmware on the Apis board, you use the 2x3-pin 6-pin ICSP (also called ISP) header with a special device called an "in-circuit system programmer" (or just "in-system programmer; yup, that's what the acronym stands for).
Many devices exist to upload firmware, including:
- The official AVR ISP mkII (no longer produced but available used)
- Using an Arduino as an ISP
- The versatile Olimex AVR-ISP-MK2
- The Adafruit USBtinyISP
Using this ISP, upload the firmware sketch to the board. To do so, follow these steps:
- Open the Arduino IDE.
- Follow these instructions to install the ATTinyCore board definitions
- Select ATTiny1634 (No bootloader)
- Plug your ISP of choice into your computer (via a USB cable) and onto the 6-pin header. There are two ways to place it on; the header is aligned such that the ribbon cable should be facing away from the board while programming. If this fails without being able to upload, try flipping the header around. This should both power the board and provide communications.
- Go to Tools --> Programmer and select the appropriate programmer based on what you are using.
- Go to Tools --> Burn Bootloader. Yes, we know that you just selected "ATTiny1634 (No bootloader)", but this step sets the fuses, which configure their internal oscillator and brown-out detection.
- Go to Sketch --> Upload Using Programmer. After several seconds, you learn whether you succeeded or failed. Hopefully it worked!
Uploading using the in-system programmer.
Important note for Linux users: You must supply permissions to the Arduino IDE for it to be able to use the ICSP, or you will have to run it using sudo. The former option is better; the latter is easier in the moment.
Note: Be sure to download and/or update drivers for your ISP.
Once it is bootloaded and connected with a LiDAR Lite sensor, you should be able to use any standard Arduino device to connect to it and read its data.
This code is intended for any generic Arduino system.
#include "Apis.h"
// Declare variables -- just as strings
String header;
String data;
// Instantiate class
Apis myLaser;
void setup(){
// Begin Serial connection to computer at 38400 baud
Serial.begin(38400);
// Obtain the header just once
header = myLaser.getHeader();
// Print the header to the serial monitor
Serial.println(header);
}
void loop(){
// Take one reading every (10 + time to take reading) seconds
// and print it to the screen
myLaser.updateMeasurements();
data = myLaser.getString();
Serial.println(data);
delay(10000); // Wait 10 seconds before the next reading, inefficiently
}The Margay data logger is the lightweight and low-power open-source data-logging option from Northern Widget. It saves data to a local SD card and includes on-board status measurements and a low-drift real-time clock. We have written a library to interface with the Margay, which can in turn be used to link the Margay with sensors.
#include "Margay.h"
#include "Apis.h"
// Declare variables -- just as strings
// Empty header to start; will include sensor labels and information
String header = "";
String data;
// Instantiate classes
Apis myLaser;
Margay Logger; // Margay v2.2
// I2CVals for Apis
uint8_t I2CVals[] = {0x50}; // DEFAULT
//Number of seconds between readings
uint32_t updateRate = 60;
void setup(){
header = header + myLaser.getHeader();
Logger.begin(I2CVals, sizeof(I2CVals), header);
initialize();
}
void loop(){
Logger.run(update, updateRate);
}
String update() {
initialize();
return myLaser.getString();
}
void initialize(){
myLaser.begin();
}The Resnik/Okapi system uses a Particle Boron for cellular telemetry – the defining capability that distinguishes it from the Margay. That telemetry component is not yet shown here; the code below is currently identical to the Margay example. See issue #21.
#include "Resnik.h"
#include "Apis.h"
// Declare variables -- just as strings
// Empty header to start; will include sensor labels and information
String header;
String data;
// Instantiate classes
Apis myLaser;
Resnik Logger;
// I2CVals for Apis
uint8_t I2CVals[] = {0x50}; // DEFAULT
//Number of seconds between readings
uint32_t updateRate = 60;
void setup(){
header = header + myLaser.getHeader();
Logger.begin(I2CVals, sizeof(I2CVals), header);
initialize();
}
void loop(){
Logger.run(update, updateRate);
}
String update() {
initialize();
return myLaser.getString();
}
void initialize(){
myLaser.begin();
}The Apis firmware runs on an ATTiny1634 and exposes an I2C register map to the host logger, laid out per NW-Device-Specification Schema 1. The default I2C address is 0x41 (ASCII 'A'); the address is stored in Page 0 and can be changed (see below).
The device exposes a flat, byte-addressable virtual address space. The controller writes a 1-byte starting address, then reads up to 32 bytes in one transaction; the firmware auto-increments. Pages are 32-byte aligned.
The map below is what the firmware on master implements (firmware patch 5, unreleased). Boards carrying the previous firmware (v0.1.x, the deployed 2019-era map) are described at the end of this section; a Schema 1 library will refuse them until they are reflashed and provisioned.
The firmware is on-demand: it idles (core in idle sleep, woken by an I2C address match or the Hall switch) until the controller writes the trigger bit, then
- Clears the ready bit, reads the chip-select bits from the control register, and consumes the trigger
- If the controller has written the readings-requested word (0x44–0x45) since the last trigger, latches it and notes the reading counter
- If the LiDAR chip is selected and the LiDAR is off: closes the 5 V switch, waits ~20 ms for the rail (680 µF through the MIC2544 at its ~227 mA limit), raises enable, and polls the LiDAR for an I2C acknowledge and the health flag in its STATUS register (bit 5) for up to 100 ms; on timeout toggles enable once more; a second failure powers the LiDAR down and latches fault chip 0 kind 1 (no acknowledge) or 5 (not initialised). On success it writes the configured sensitivity
- If the LiDAR chip is selected and powered: writes ACQ_COMMAND (any non-zero value starts a measurement on the v3HP), polls STATUS bit 0 (busy) until clear, and reads the 16-bit range and the signal strength. The LiDAR's mode pin is not used (see issue #24)
- If the accelerometer chip is selected: reads the 3-axis accelerometer (LIS3DH) and the stored offsets
- Loads status, fault code, and the reading counter, then sets the ready bit, with interrupts disabled so a page read never straddles the update
- Powers the LiDAR down if the request was for a single reading (0 or 1) or the requested count is now complete; otherwise leaves it powered for the next trigger. A batch with no trigger for 2 s is abandoned: LiDAR off, fault chip 0 kind 2
Serial output (range and axes per reading) exists only when the sketch is compiled with APIS_DEBUG defined.
Three 32-byte pages. Page 0 (identity) is copied from EEPROM at boot; Page 1 (calibration) is copied from EEPROM byte for byte at boot and again after each zero (a blank word reads as 0); Page 2 (status and sensor data) lives in SRAM. Pages renumbered 2026-09-23 (spec 4c3b18d): calibration is Page 1 at 0x20, data Page 2 at 0x40.
Page 0 (0x00–0x1F) – Identity (EEPROM 0xC0–0xDF, written by NW-Provision)
Block 0 (0x00–0x07) Core identity
0x00 0x01 Schema (NW-Device-Specification v1)
0x01–0x04 'A','p','i','s' Device name (ASCII)
0x05–0x07 0x00,0x00,0x00 Null padding
Block 1 (0x08–0x0F) Version
0x08 HW major (from EEPROM)
0x09 HW minor (from EEPROM)
0x0A FW patch written by the firmware into the served copy (FW_FW_PATCH),
so it always matches the code running; the CRC of the served
copy is recomputed
0x0B–0x0D 0x00,0x00,0x00 Unused (combined repo)
0x0E–0x0F 0x00,0x00 Reserved
Block 2 (0x10–0x17) Serial number
0x10–0x11 0x41,0x00 Board type ('A' = 0x41, hardware major 0; NW-Registry 0x4100)
0x12–0x13 [provisioning] Group ID
0x14–0x15 [provisioning] Unique ID
0x16–0x17 0x00,0x00 FirmwareID (legacy, reserved)
Block 3 (0x18–0x1F) Integrity + administration
0x18–0x1C 0x00 ×5 Reserved
0x1D 0x4E Magic byte ('N')
0x1E [computed] CRC-8/SMBUS of bytes 0x00–0x1D
0x1F 0x41 I2C address (writable; 0xFF = use default 0x41)
If the CRC in EEPROM does not match, or the schema byte is not 0x01, the firmware still runs but sets the Report register to "unit: Page 0 checksum" (0xE3); the board needs provisioning.
Page 2 (0x40–0x5F) – Status and sensor data (SRAM)
Chip table (index for status fault bits, control chip-select bits, and the Report register):
| Index | Chip | Measurements |
|---|---|---|
| 0 | LiDAR Lite v3HP | range, signal strength |
| 1 | LIS3DH accelerometer | X, Y, Z |
Block 0 (0x40–0x47) Universal block (NW-Device-Specification)
0x40 Status bit 0 ready; bit 1 LiDAR fault; bit 2 accelerometer fault;
bit 7 pan-fault. Read-only, live.
0x41 Control writable. bit 0 trigger a reading now (the firmware clears it
when the reading starts); bit 1 measure LiDAR; bit 2 measure
accelerometer (power-up: both set); bit 7 sleep – defined by
the spec, not yet implemented here (cleared by the firmware).
Any write to Control clears the Report register.
0x42–0x43 Reading counter uint16, little-endian, +1 each time ready is set; 0 at boot
0x44–0x45 Readings writable, uint16 little-endian: how many readings the controller will
requested trigger with the LiDAR held powered; 0 (boot value) = one per trigger,
powered down after each. A new write replaces the remainder.
0x46 Config writable. bits 1:0 LiDAR sensitivity mode (see below)
0x47 Report latched until the controller writes Control: the most recent report, a fault (its chip's status bit is set too) or a notice (no status bit): bits 7-5 chip (7 = the unit), bits 4-0 kind (1 no acknowledge, 2 timeout, 5 not initialised, 6 reset, 9 calibration stored, 10 batch abandoned).
bits 7–5 chip (0 LiDAR, 1 accelerometer, 7 unit);
bits 4–0 kind (1 no-acknowledge, 2 timeout, 3 Page 0 checksum,
5 not initialised, 6 reset since the controller last wrote Control)
Block 1 (0x48–0x4F) LiDAR Lite
0x48–0x49 Range [cm] little-endian int16; -9999 on timeout
0x4A Signal strength uint8
0x4B–0x4F Reserved
Block 2 (0x50–0x57) Accelerometer
0x50–0x51 Accel X little-endian int16 (raw counts, >> 4)
0x52–0x53 Accel Y little-endian int16
0x54–0x55 Accel Z little-endian int16
0x56–0x57 Accel temperature, the LIS3DH OUT_ADC3 word as read (low byte first): relative, 1 digit per °C in the high byte (patch 3)
Block 3 (0x58–0x5F) 0x58–0x59 zero generation, uint16 LE, the Page 1 value, served with every reading (patch 5)
0x5A–0x5F Reserved
Check bit 0 of 0x40 before using any measurement; if clear, the data registers are stale. Compare the reading counter with the last value read to know whether a new reading has happened since.
At boot the Report register reads 0xE6, "unit: reset since the controller last wrote Control", so a controller can tell that the device restarted (and lost its volatile configuration) since it last configured it. The first write to Control clears it.
Page 1 (0x20–0x3F) – Calibration (EEPROM 0xE0–0xFF)
Block 0 (0x20–0x27) Current zero: Offset X, Y, Z int16 LE; accel temperature word int16 (as today)
0x20–0x21 Offset X little-endian int16
0x22–0x23 Offset Y little-endian int16
0x24–0x25 Offset Z little-endian int16
0x26–0x27 Accel temperature word when the offsets were taken (patch 3)
Block 1 (0x28–0x2F) Previous zero, same form
Block 2 (0x30–0x37) The zero before that, same form
Block 3 (0x38–0x3F) 0x38–0x39 zero generation, uint16 LE: zeros stored since manufacture (0 = never);
0x3A–0x3F reserved
Offsets are written when the Hall-effect switch is triggered with the magnet (the board's "set level" action). A never-written word (0xFFFF) reads as zero. Storing a zero (patch 5) shifts Block 1 to Block 2 and Block 0 to Block 1, writes the new zero into Block 0, and adds one to the generation, byte by byte with compare-before-write; the served page and the mirror at 0x58 follow at once, and the Report register latches 0x29 (calibration stored) as before. Page 1 is stored in bus order from patch 5 (the earlier patches wrote the words big-endian), so a unit zeroed under patch 3 or 4 needs a new zero after reflashing.
Write one of the following values to the config register (0x46, bits 1:0) to set the LiDAR Lite measurement sensitivity:
| Value | Description |
|---|---|
0 |
Balanced range and noise (default) |
1 |
Higher sensitivity; reduced maximum range |
2 |
Lower sensitivity; extended maximum range |
3 |
Maximum range mode |
Configuration is volatile: the controller sets it after every power-up.
Page 0 byte 0x1F holds the address; a write to register 0x1F persists it (compare-before-write) and it takes effect on the next power cycle. 0xFF means "use the default", 0x41. Several Apis boards can share a bus by giving each its own address; choose one not listed in the NW-Device-Specification bus-occupancy table.
A Schema 1 library's begin() reads Page 0 Block 0 and refuses the device unless the schema byte is 0x01, the name spells Apis, and the firmware patch at 0x0A is at least the version the library was written for. A refused begin() means: reflash, then provision with NW-Provision. Check the return value of begin() when deploying.
A single 32-byte page, one byte served per request; status and identity mixed; no schema byte. Kept here for boards that have not been reflashed. Default address 0x50.
| Address | Name | R/W | Description |
|---|---|---|---|
0x00 |
REG_STATUS |
R | LiDAR initialised: 1 = ready, 0 = busy |
0x01–0x04 |
REG_NAME_0..3 |
R | Device name: 'A','p','i','s' |
0x05–0x07 |
REG_HW_MAJOR, REG_HW_MINOR, REG_FW_PATCH |
R | Versions (compiled in) |
0x08–0x09 |
REG_RANGE |
R | Range, little-endian int16 [cm] |
0x0A |
REG_SIGNAL_STR |
R | LiDAR Lite signal strength (0–255) |
0x0B |
REG_CONFIG |
R/W | Sensitivity mode [bits 1:0] |
0x0C |
REG_I2C_ADDR |
W | Write to change I2C address (EEPROM byte 6) |
0x10–0x15 |
REG_ACCEL |
R | Accel X/Y/Z, three little-endian int16 values |
0x18–0x1D |
REG_OFFSET |
R | Accel offsets X/Y/Z (EEPROM bytes 0–5) |
This is what we used for our build; you can be creative based on materials and availability.
- Main enclosure
- Polycase box WC-20F (clear lid)
- 2x #4 screws to mount Apis board in box
- Cable gland (Heyco M4365) for cable to LiDAR Lite
- Strain-relieved cable gland (Heyco M4425) for cable to logger
- Desiccant packs
- LiDAR Rangefinder and attachment to enclosure
- LiDAR Lite sensor
- 4 sealing screws: #4-40 x 3/8"
- 4 washers for #4 screws
- 4 cap nuts for #4-40 screws
- Mounting plate
- Material: Acetal (Delrin) sheet: 1/4" thick. We commmonly use 12x24" black; the black pigment increases its UV resistance
- Rectangular dimensions for mount: 127 x 95.25 x 6.35 mm (5.00" x 3.75" x 0.25")
- Design on Easel for X-carve (see also CNC files here). Note the 7 mm depth to ensure that the bit cuts all the way through the Acetal; use a piece of scrap material on your cutting bed if you want to protect it.
- Mounting plate fasteners
- 1/4"-20 hardware to attach the box to the mounting plate
- Bolts: 1" long; hex head convenient; zinc-plated medium-grade (Grade 5) recommended for lower price with good corrosion resistance
- Nuts: Zinc-plated Grade 5
- Washers: Zinc-plated SAE or USS
- Lock washers: We typically use split-lock washers, but tooth-lock washers are good for high-vibration environments.
- 2 U bolts: 1/4"-20, inner diameter 3/4" to 1 3/4", to attach the mounting plate to a pipe. We typically mount this sensor on 3/4" pipe or conduit, and recommend a U bolt designed to fit this (1/4"-20, 1 1/8" inner diameter). Weather/corrosion resistance is helpful, especially if you are concerned about later removing the U bolts.
- 1/4"-20 hardware to attach the box to the mounting plate
- Cable to logger
- 3 m (or less) 4-conductor AlphaWire, stripped and tinned at both ends. Other cables will work too; this is what we have found to be highest quality and reliability. We cannot guarantee successful I2C communications over cables longer than 3 meters.
Mounting plate perspective view in Easel for easy integration with the X-carve series of lower cost CNC routers.
Prior to assembly, ensure that you have:
- Uploaded the firmware to the Apis board
- Fabricated the mounting plate (see also the Easel online CNC setup) if desired.
-
Drill and tap 12 mm holes in the side of the box. Use a M12-1.5 tap for the threads.
-
Install the Apis board as shown below using two of the #4 self-tapping screws.
- Using the sealing screws, cap nuts, and washers, install the LiDAR Lite sensor onto the lid. By mounting the LiDAR Lite at an angle, you can fix it to the box lid in a way that still allows the box to open and close properly. The cap nuts go on the outside of the housing.
-
Thread the cables through the cable glands and attach them to the screw terminals. A 1.8 mm flat-head screwdriver can be very useful for this. Note that these cables cross the board in the above image (upper left) -- and that (unlike in the image!) you should do this after the board is in the box.
-
Using the switch in the box, select the desired communications protocol. For most of our uses, this is I2C.
-
Attach the cable to the data logger.
-
Test the LiDAR Lite unit.
-
When satisfied with the tests, turn off the data logger and place a protective cover over the lenses of the LiDAR Lite for safety during transport. We have a set of "safety glasses" available for 3D printing. You may want to secure these in place with electrical tape.
-
Place desiccant in the box. I typically install two small desiccant packs on the side of the board above the switch and large capacitor and pack them in so they are unlikely to move; this is in order to keep the indicator LED visible.
-
Securely screw the lid onto the box to seal the LiDAR Lite + Apis unit.
-
Mark the corner of the box next to the Hall-effect sensor, and mark the orientations of the roll and pitch axes. The pitch axis should be positive when the long strain-relieved cable gland tilts upwards. The roll axis should be positive when, when looking at the side of the assembly such that the long strain-relieved cable gland is on the left and the laser rangefinder is pointed up, the laser rangefinder rolls towards you.
Pitch, roll, and Hall-effect calibration location on the assembled unit. The "zero" oval cutout on the lower center of the box face marks where to tap the magnet.
-
Place the box on a measured flat surface and tap the magnet to the marked location by the Hall Effect sensor. This will appropriately zero the offsets for the sensor and increase its near-horizontal accuracy significantly. This must be done when the sensor is powered. From firmware patch 3 the magnet only starts the zero: tap it at the mark, at boot or at any time, and take it away. The LED lights and stays on while the firmware averages samples at the accelerometer's 10 Hz rate until the mean of every axis has settled (at least 3.2 s, at most 100 s), and goes out when the zero and its temperature are stored. Keep the unit still until then. From patch 5 the unit keeps the two zeros before the current one, with a count of zeros stored since manufacture that every reading carries, so a logger can tell when a zero was retaken. When connected to a logger, hold the magnet at the mark, hit the "RESET" button (e.g., on a Margay logger), and remove the magnet once the LED is on. Doing this while connected to a computer is recommended in order to see the first reading on the serial monitor and double check that the zeroing/calibration is appropriate. For a convenient magnet holder, you can use our [3D-printable magnetic wand][3Dprint], which holds a small rare-Earth magnet. This may be a generic part, though this 3/8" x 1/8" Neodymium Disk Magnet works well in our experience.
-
Use the 1/4"-20 hardware to attach the LiDAR Lite box to the mounting plate. The bolts pass through the center holes on the tabs on either side of the box, with their heads towards the box lids.
Note: Mounting plate holes currently too small for these; will need to be updated. Currently using #8 hardware. Figures for pitch+roll have 1/4-20 -- I probably drilled it out wider for these.
- (Can wait for field installation) attach the unit via its mounting plate to the appropriate pipe, post, etc. This typically involves the U bolts, noted above. Curved EMT conduit can be helpful for providing a way to select the angle of the sensor. Although we use a single 45-degree bend piece of conduit in the images below, we might suggest attaching a 90-degree bend conduit first, and then a 45-degree bend as necessary to adjust the sensor away from a direct down-looking view; the sensor will attach directly to the convex side of the bend instead of bridging over airspace, which required us to use rocks as shims to reduce mounting-plate flexure. (This suggestion, however, increases torque on the mast; future field testing is needed to determine the best method.) Note: The LiDAR Lite unit will likely give a return only if its angle to the surface that it is measuring is steeper (i.e., more orthogonal) than 45 degrees.
Lab mock-up of field installation for LiDAR Lite. The boxes at right contain Northern Widget Margay data loggers with a single cable gland to connect to the Apis box. The two posts next to them provide examples of how to connect the 3/4" EMT conduit to some fixed point in the environment, either the side of a flat(ish) wall (right) -- though the brackets aren't necessary or even always good, since we can bolt right through the pipe -- or to a flat(ish) surface using a floor flange. We drilled holes through the conduit to attach 1/4" eye bolts (1/4"-20, 1.5" long) using nuts, lock washers, and washers, to the conduit. These eye bolts then held turnbuckles to which we attached cables (lower left). The other end of the cables can be attached via sleeve or wedge anchors to rock, or to other sturdy structures. The LiDAR Lite + Apis is in the upper left corner, albeit attached in a way that would have it looking up... unless it were attached to the end of the 90-degree bend.
- 3/4" EMT rigid conduit
- Straight: main mast
- 90-degree bend
- 45-degree bend
- 3/4" Conduit screw-down connectors (to join multiple pieces of conduit)
- 3/4" Conduit-to-threaded connectors (to link smooth conduit to threaded 3/4" plumbing, needed only if you use a floor flange)
- Floor flange (1, if you want to attach to a flat surface)
- 1/4-20 x 1.5" eye bolts (3, +1 in case you bend/break one)
- 1/4" x 2+" long sleeve or wedge anchors; 4 for the floor flange or 2 for bolting into the side of a rock. Extras suggested, as these can be broken during installation.
- Turnbuckles; I suggest getting 3 that are threaded all the way down (as shown in the picture above). Get an extra in case you break one.
- 1/8" metal cable
- 1/8" cable clamps (x6, +1 in case you lose the nuts)
- 1/8" metal cable turns (x6; if you lose one, don't worry; these are nice for durability but not totally necessary)
- 3/8" x 2.5+" long sleeve or wedge anchors for the cables; these are less breakable than their 1/4" cousins, but you might still want an extra one.
- Extra 1/4"-20 hardware. I almost always end up needing this.
- Cable management (keep secure and prevent from flapping in the wind, which can cause damage)
- Cable ties (zip ties). Ensure that these are UV-resistant; many black ones are.
- Electrical tape
- Optional: 2x ~1-3/4" hose clamps if mounting a data-logger box for the Margay on the main mast. Longer hose clamps (or multiple 1-3/4" clamps in series) for larger logger boxes, so long as they can remain stable on the mast.
You might not need the guy wires and associated hardware if you bolt your assembly to the side of something (like a rock or wall). Some guy wires are generally encouraged.
Placing and leveling the base.
Installing the base using wedge anchors.
Installing the conduit and anchoring it with eye bolts and turnbuckles. Before going out to the field, we strongly suggest you pre-drill the holes and pre-install the eye bolts.
Tightening the cable around the bolt in the rock using the cable clamp.
Aiming the LiDAR Lite unit at the river. In future models, we are considering adding peep sights to the mounting bracket. Professor Billy Armstrong in the photo.
The quality of any zeroing with the Hall-effect sensor is limited by the accelerometer itself: from firmware patch 3 the zero is an average with about 0.01° of noise, but the LIS3DH's offset drifts by about 0.5 mg per °C, which is about 1.7° across a 60 K season after the zero. The chip's temperature is logged beside pitch and roll (the AccelT column) so that a per-unit correction can be fitted once bench data exist; until then, measure and record the orientation of the field-mounted unit by hand as an additional check. The survey behind these numbers is in the private repository NorthernWidget-Skunkworks/Inclinometer-Selection.
Fully installed clifftop unit Note data-logger box attached with cable ties, as well as the mounting-plate attachment. For the latter, we used a rock as a shim with a 45-degree piece of EMS conduit. However, it may have been better to use a 90-degree piece of conduit and a 45-degree piece of conduit together to keep us from needing this shim -- though this would have increased torque on the main mast.
Alternative method: installing on the side of a rock.
Full mast installed on the side of a rock. *Note the LiDAR Lite + Apis and the data-logger box.
Units programmed before Schema 1 carry board type 0x6C00 (the Symbiont-LiDAR code) in the old 8-byte serial block and answer at I²C address 0x50. They are refused by a Schema 1 library until reflashed and provisioned; see Register map and firmware internals.
Support for this project provided by:

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.