Skip to content

feat: add support for the new Vitocal 200-A - #819

Open
lackas wants to merge 4 commits into
openviess:masterfrom
lackas:support-obng-heatpump
Open

lackas wants to merge 4 commits into
openviess:masterfrom
lackas:support-obng-heatpump

Conversation

@lackas

@lackas lackas commented Sep 10, 2026

Copy link
Copy Markdown
Contributor

Adds support for the freshly released Vitocal 200-A by adding systemController and outdoorUnit to SUPPORTED_DEVICE_TYPES, both auto-detected as HeatPump. The indoor unit carries nothing but device.serial and device.variant, so it stays out. Dumps from home-assistant/core#181876 are added as test data.

The dump is the first to declare heating.sensors.volumetricFlow.allengra deprecated, which trips the deprecation gate because three getters still read it and the replacement is on no known device, so check_deprecations.py gets the ignore list its docstring has promised since #707.

This branch has not been deployed

No deployments
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment