p_pid_kd_proc config field is silently no-op for DC/BLDC motor types (only implemented in FOC position control) #932

Open

Description

@Kenaiwolf

Summary

p_pid_kd_proc is a mc_configuration field (a second, independent "process D-term" gain for position control, computed from raw position feedback rather than from PID error) that is serialized/deserialized identically for all motor types via the shared config struct, but is only read inside the FOC position-control code path. For MOTOR_TYPE_DC/MOTOR_TYPE_BLDC, setting this value from VESC Tool has zero effect — the field is silently ignored rather than rejected or flagged as unsupported.

Where it's used (FOC only)

foc_run_pid_control_pos() in motor/foc_math.c reads it into a local kd_proc and computes a distinct derivative term from the raw angle delta (not from PID error): foc_math.c:416-419

float kp = conf_now->p_pid_kp;
float ki = conf_now->p_pid_ki;
float kd = conf_now->p_pid_kd;
float kd_proc = conf_now->p_pid_kd_proc;

and applies it here: foc_math.c:453-460

motor->m_pos_dt_int_proc += dt;
if (angle_now == motor->m_pos_prev_proc) {
d_term_proc = 0.0;
} else {
d_term_proc = -utils_angle_difference(angle_now, motor->m_pos_prev_proc) * error_sign * (kd_proc / motor->m_pos_dt_int_proc);
motor->m_pos_dt_int_proc = 0.0;
}

Where it's absent (DC/BLDC)

run_pid_control_pos() in motor/mcpwm.c — the position-control PID function used for MOTOR_TYPE_DC/MOTOR_TYPE_BLDC — has no reference to p_pid_kd_proc anywhere in its body; it only computes a single error-based D-term via p_pid_kd/p_pid_kd_filter: mcpwm.c:1246-1283

Confirmation the field is generic, not FOC-scoped, in the schema

The field is defined in the shared mc_configuration struct in datatypes.h and is unconditionally serialized/deserialized in confgenerator.c, with no motor-type guard — i.e., nothing in the wire protocol or config schema indicates this field is FOC-only: datatypes.h:1

Impact

Users running MOTOR_TYPE_DC/MOTOR_TYPE_BLDC with position control (e.g. steering/actuator applications) who tune p_pid_kd_proc via VESC Tool expecting it to affect the D-term will see no behavioral change whatsoever, with no warning/error — the value is stored but never consumed.
This is a more severe case of the same class of problem as the previously reported p_pid_kd_filter divergence: rather than being implemented differently between motor types, p_pid_kd_proc is not implemented at all outside FOC.

Suggested fix

Either port an equivalent "process D-term" computation to run_pid_control_pos() in motor/mcpwm.c for DC/BLDC motor types, or
Hide/disable the p_pid_kd_proc field in VESC Tool's UI when motor type is not FOC, and/or document in the field's tooltip/description that it is FOC-only, so users don't waste time tuning a parameter with no effect.

Environment

Custom hw_410-based hardware (STM32F405/F407, VESC 4.x-class board), DC motor with A/B hall sensor, MOTOR_TYPE_DC, CONTROL_MODE_POS (position control) for a steering/trim state machine application. Related to a previously reported divergence in p_pid_kd_filter behavior between FOC and DC/BLDC position control.

--- foc_math.c:416-460 mcpwm.c:1246-1283

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions